17. Comparison of Tonovet® and Tonovet plus® tonometers for measuring intraocular pressure in dogs, cats, horses, cattle, and sheep
Liga Kovalcuka, Aija Mālniece, and Jana Vanaga
Veterinary World, 17(2): 384-388

Liga Kovalcuka: Clinical Institute, Faculty of Veterinary Medicine, Latvia University of Life Sciences and Technologies, Jelgava, LV-3004, Latvia.
Aija Mālniece: Clinical Institute, Faculty of Veterinary Medicine, Latvia University of Life Sciences and Technologies, Jelgava, LV-3004, Latvia.
Jana Vanaga: Clinical Institute, Faculty of Veterinary Medicine, Latvia University of Life Sciences and Technologies, Jelgava, LV-3004, Latvia.

doi: 10.14202/vetworld.2024.384-388

Article history: Received: 29-11-2023, Accepted: 24-01-2024, Published online: 16-02-2024

Corresponding author: Liga Kovalcuka

E-mail: kovalcuka@gmail.com

Citation: Kovalcuka L, Mālniece A, and Vanaga J (2024) Comparison of Tonovet® and Tonovet plus® tonometers for measuring intraocular pressure in dogs, cats, horses, cattle, and sheep, Veterinary World, 17(2): 384–388.
Abstract

Background and Aim: Reference ranges for intraocular pressure (IOP) in healthy animals are device-specific; therefore, it is strongly recommended to use appropriate reference values according to the device. Therefore, our aim was to compare IOP readings made by TonoVet® and TonoVet Plus® in healthy dogs, cats, sheep, cattle, and horses. We compared IOP values measured by TonoVet® and TonoVet Plus® tonometers in clinically normal eyes of dogs, cats, horses, cattle, and sheep.

Materials and Methods: Five groups comprising 20 animals each of dogs (various breeds, 9 months–10 years old, 14 females, 6 males), cats (various breeds, 6 months–12 years old, 8 females, 12 males), horses (various breeds, 5–12 years old, 12 females, 8 males), cattle (Holstein, 1–7 lactation, female), and sheep (Latvian Darkhead ewes, 1–8 years old) were included in the study. Both eyes of all animals were subjected to ophthalmic examination, including evaluation of IOP by rebound tonometry using TonoVet® and TonoVet Plus® devices. Normality was determined using the Shapiro–Wilk test. The independent t-test was used to determine differences between IOP values in the right and left eyes and between both tonometers. This study was approved by the Ethical Commission of the Latvia University of Life Sciences and Technologies (Nr. LLU_Dzaep_2022-2-4).

Results: No differences in IOP between the right and left eyes were found in all cases (p > 0.05). The mean IOP ± standard deviation values in both eyes for TonoVet® and TonoVet Plus® tonometers were as follows: for dogs, 15.25 ± 2.73 mmHg and 19.65 ± 3.46 mmHg; and in cats, 18.88 ± 3.98 mmHg and 18.78 ± 4.26 mmHg, respectively. In horses, mean IOP was 22.15 ± 3.74 mmHg and 24.28 ± 3.00 mmHg; in cattle, 24.73 ± 2.89 mmHg and 23.28 ± 2.97 mmHg; and in sheep, 18.05 ± 3.54 mmHg and 22.49 ± 4.66 mmHg, respectively. Significant differences in IOP values were observed between the tonometers in sheep, dog, and horse groups (mean difference –4.40, –4.48, and 2.13, respectively).

Conclusion: This study showed significantly higher IOP values measured by the TonoVet Plus® tonometer in dogs and sheep.

Keywords: cats, cattle, dogs, horses, sheep, TonoVet plus, TonoVet.